A WILKINSON STAR LIMITED PRODUCT 01-19 ISSUE 1
Spot mode
When welding in the spot mode use the adjuster to
navigate the On LED (1). Press the adjuster (the LED
will ash) and adjust to the desired spot me. Press
the adjuster to save the parameter (the LED will
stop ashing).
Use the adjuster to navigate the O LED (2). Press
the adjuster (the LED will ash) and adjust to the
desired o me. Press the adjuster to save the
parameter (the LED will stop ashing).
Example:
The On me is set at 1 second and the O me at 5
seconds.
When the torch switch is operated the arc will be
on for 1 second and then o for 5 seconds and will
repeat unl the torch switch is released.
Hybrid (Mix) mode:
When operang in hybrid mode it is necessary to
set the hybrid frequency and me.
When in Mix mode TIG use the adjuster to navigate
the Hz LED (1). Press the adjuster (the LED will ash)
and adjust to the desired frequency. Press the
adjuster to save the parameter (the LED will stop
ashing).
Use the adjuster to navigate the DC duty % LED (2).
Press the adjuster (the LED will ash) and adjust to
the desired duty percentage. Press the adjuster to
save the parameter (the LED will stop ashing).