Page 22
10. MMA parameter selector
11. Operation mode selector
6.1.1 Display of TIG parameters
Figure 6-2 TIG parameter display
1) Pre-flow time indicator. When the indicator is on, it indicates the pre-flow protection
time.
2) Initial current indicator. When the indicator is on, it indicates the initial current.
3) Up-slope time indicator. When the indicator is on, it indicates the time until the initial
current reaches the peak current.
4) Peak current indicator. When the indicator is on, it indicates the welding current.
5) Down-slope time indicator. When the indicator is on, it indicates the time until the
peak current drops to the finish current.
6) Finish current indicator. When the indicator is on, it indicates the finish current.
7) Post-flow time indicator. When the indicator is on, it indicates the post-flow time.
8) Spot welding time indicator. When the indicator is on, it indicates the spot welding
time.
When the machine is started, in idle state (the state when the welding torch is not being used,
the operation panel has no operation for over 5s, and the machine is not welding), or when
switching mode, the TIG parameter indicator shows the peak current, which can be adjusted
by rotating the encoder. The indicator flashes during the adjustment, but does not flash
before/after adjustment.