6.1.5 Selection of arc starting mode
1) Before welding, press the welding mode key to switch between lift arc starting and
HF arc starting, and select the corresponding mode based on the process requirement.
2) If the indicator is on, it indicates that the HF arc starting mode has been selected.
3) If the indicator is on, it indicates that the lift arc starting mode has been selected.
6.1.6 Enabling remote control
1) Before welding, press the remote control function key to enable the remote control
function.
2) If the indicator is on, it indicates that the remote control function has been enabled. If
the remote controller is connected, it controls the welding current. If no remote controller
is connected, the welding current is controlled by the panel adjuster.
3) If the indicator is not on, it indicates that the remote control function has been disabled,
and the welding current is being controlled by the panel adjuster.
6.1.7 Smart gas
Press the key to enable Smart gas. If the indicator is on, it indicates that the
machine is in Smart gas mode. This function automatically matches the appropriate post-flow
time according to the user’s welding specifications, effectively saving argon.
6.1.8 Parameter adjustment knob
1) Rotate the adjustment knob to adjust the parameter.
2) Rotate the knob clockwise to increase the value, and counterclockwise to decrease the
value.
3) When the knob is rotated, the adjustment is displayed in the parameter display area. The