4-7
Section 1 General Information
9803/9330
Section 1
4-7
Issue 1
Operation
Set Mode
Pressing the SET button on the EMS panel enters the Set
Mode menu. Pressing the Scroll Up and Scroll Down buttons
will cycle through the entries, and pressing the ACK button
will select an item. Pressing the SET button will return the
operator to the normal display.
The Set Mode entries and their descriptions are as follows:
Switches and Controls (cont’d)
EMS Panel (cont’d)
Menu Modes
The EMS Panel has three Menu modes: Set Mode,
Diagnostic Mode and Calibration Mode. The first two
modes are designed to allow the operator to monitor the
operation of the vehicle. The third mode allows properly
trained JCB personnel to adjust the calibration of the system
and is detailed in the machine service manual.
Entry Format Details
CLOCK: 12/24? 24 Use the arrow keys select 12/24 hour format. Then press "ACK" to accept the format.
XX:XX This will display the currently set time. Use the arrow keys to set the hours and press "ACK"
to accept the value. Now do the same for the minutes.
HIGH FLOW XXXXX XXXX The total hours that the high flow or double acting high flow features are in use. If the input
for these features is active, then hours will be accumulated. The left number shows the
total hours (99, 999 max). The number on the right shows the number of hours used since
the last service (9, 999 max). This value will be flashing and can be reset to zero by pressing
the "ACK" button.
AUTO IDLE T: XX SECONDS This is the auto idle delay time. The scroll keys increase/decrease the delay time from a
minimum of 5 seconds up to a maximum of 30 seconds. Press the "ACK" button to accept
the value. The default value for this setting is 5 seconds.
LANGUAGE: English Language set up. Use the scroll keys to change between pre-programmed alternative
languages and English. Press the "ACK" button to accept.
INT WIPER S: Wiper SPD-X Intermittent wiper speed. Use the scroll keys to increment/decrement the delay between
stroke time. There are 10 different speed settings. Press the "ACK" button to accept the
new value.
DATE: XX-XX-XXXX The current date. Use the scroll keys to increment each value. Press the "ACK" button to
move from year to month. Press it again to move from month to day. One more press will
store the value into memory.
Monitor Messages
Repetitive Messages
The following messages are repetitive, i.e. they will be displayed for as long as the source of the message still requires it to be
displayed. The table shows which messages have buzzers. The 'ACK' column indicates whether or not the buzzer can be
silenced by pressing the "ACK" button. In some cases, the fact that a message has been triggered is stored into the EMS
memory. Contact your dealer if any of these messages occur.
Message Meaning Buzzer ACK
ALTERNATOR The engine is running and the alternator is not charging. YES YES
AUTO IDLE The auto idle feature is active and therefore the system has been dropped to low idle. NO N/A
BATT VOLTS The battery voltage is out of range. YES NO
NO THROTTLE This will be displayed whenever there is a throttle related error. YES YES
OIL PRESS The engine is running with no oil pressure. YES NO
RECALIBRATE The ECU-MIDI has not had its throttle calibrated. YES YES
SENSOR VOLT The sensor voltage is less than 4V. YES YES
SETUP RQD Either the EMS or the ECU-MIDI requires set-up. YES YES