EN - 14 BA-0006 • 2020-02-08
6 Putting into operation SynMag 2600/3100/3600/4100/5100
6.4 Mains port
1 Insert the mains plug into the appropriate socket.
6.5 Welding
To achieve high-quality welding results, it is important to choose the correct voltage level as well as the
optimum wire feed speed and gas quantity.
1 Set the cylinder pressure reducer: set the required shielding gas volume on the cylinder pressure reducer
(6–18 l/min). The gas volume to be set primarily depends on the strength of the welding current.
2 Insert the welding wire: select the welding wire in line with the material to be processed. Attach the
appropriate contact tip and wire feed roll for the welding wire.
3 Use the welding voltage selector switch to select the welding voltage.
4 Set the wire feed speed.
5 Press the torch trigger to start welding.
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
Personal injuries or material damage
Incorrect mains connection can result in personal injuries and material damage.
• Only attach the components when the mains plug is disconnected.
• Connect the system only to the sockets which have protective earthing conductor.
• Only qualified personnel are permitted to perform work on the device or system.
Do not operate the voltage selector switch while welding.