Lighting after installation
The Jetmaster should not be run hard until all cement and plasterwork is completely dry and cured. When
installation has involved building in cement mortar allow:-
A. 7 days drying time if the house has other forms of heating.
b. At least 14 days if the installation is in a new or unoccupied property, or is tted into a completely new
chimney breast.
Chimney Sweeping
We recommend that chimneys should be swept at least twice a year during the burning season. More frequent
sweeping may be necessary where res are burned throughout the year or where low grade woods or bituminous
coal are used as fuels. The chimney can be swept through the re. The re is provided with removable tertiary air
tubes and V board bafes to facilitate chimney sweeping and for the removal of soot from the unit. See Servicing
Instructions.
Handing Over
l
Read the Users instructions and instruct the user on the operation of the re and cleaning methods. Leave
instructions with the user.
l
The user should be told that any odours are due to the newness of materials and should disperse after a few
hours operation.
l
The user should be informed that the re should be serviced annually and the chimney checked for ue pull
and blockage.
Advise the customer on the operation of the air control valve
Advise the customer on the importance of an adequate air supply
Advise the customer on the importance of regular servicing and chimney sweeping
The serial number is located on the data plate behind the door on the front of the re
Finally, record the serial number and installer/supplier details at the front of this
instruction book
23