Installation Instructions
Introduction
READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION. CLOSE ATTENTION
TO THE DETAILS OF INSTALLATION WILL ENABLE YOU TO GET THE BEST RESULTS FROM YOUR
FIRE.
NOTE: THESE INSTRUCTIONS SHOULD BE RETAINED FOR FUTURE REFERENCE.
There are three essential requirements for a successful installation.
A. The re must be correctly tted into the recess and surround.
B. The chimney must be swept and of correct dimensions, be suitable for use with a wood burning stove and
be terminated clear of any possible wind effects.
C. There must be an adequate supply of air into either the appliance if an external air supply is used, or
adequate air supply into the room if an external air supply is not used.
Dimensions
The table of installation data on page 5 contains all the dimensional information necessary to allow the installation
to be properly planned.
Regulations
In the United Kingdom the installation must be in accordance with:-
l
The Building Regulations issued by the Department of the Environment or the Building Standards (Scotland)
(Consolidation) Regulations issued by the Scottish Development Department.
l
All relevant codes of practice and relevant parts of any local regulations, including those referring to National
and European standards.
l
In your own interest and for safety, in the United Kingdom, it is the law that all solid fuel appliances are
installed by competent persons, a registered installer or approved by your local building control ofcer. The
Heating Equipment Testing and Approval Scheme (HETAS) require its members to work to recognised
standards.
l
In other countries the installation must also conform to the national and local regulations in force. This may
include only the use of permitted fuels in some countries.
THIS APPLIANCE IS DESIGNED AND APPROVED TO BURN WOOD WITH THE DOOR CLOSED.
WHEN A COAL GRATE IS INSERTED, THEN COAL, SMOKELESS FUELS AND OTHER SOLID FUELS MAY
BE BURNT.
THIS APPLIANCE IS NOT DESIGNED TO BURN GAS.
Important Points to Note before Starting Installation.
Convection Inlet
This must never be restricted. The re can be tted on a small plinth for aesthetic reasons also this will help
prevent the ingestion of any ash from the hearth into the air inlet.
6

Table of Contents

Other manuals for Jetmaster 60i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Jetmaster 60i and is the answer not in the manual?

Jetmaster 60i Specifications

General IconGeneral
BrandJetmaster
Model60i
CategoryStove
LanguageEnglish

Related product manuals