EasyManua.ls Logo

JLG 4017PS - Operator Maintenance Instructions; Fuel System

JLG 4017PS
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 7 - Lubrication and Maintenance
7-4 31200345
7.4 OPERATOR MAINTENANCE INSTRUCTIONS
Fuel System
A. Fuel Level Check
3513PS, 4013PS
4017PS Before S/N 1160006867
1. Check fuel gauge (1) located on instrument panel in cab.
2. If fuel is low, proceed to fuel source and perform “Shut-Down Procedure” on page 4-3.
3. Open rear access door (2).
4. Turn fuel tank cap (3) to remove from filler neck (4).
5. Add diesel fuel as needed.
6. Replace fuel tank cap.
7. Close and secure rear access door.
Note: Replenish diesel fuel at end of each work shift to minimize condensation.
NOTICE
EQUIPMENT DAMAGE. Do not allow machine to run out of fuel during operation. See
Engine Operation & Maintenance Manual for details prior to servicing.
8
OW1150
OW0990
OZ2081
1
OZ0660
2
4
3

Table of Contents

Other manuals for JLG 4017PS

Related product manuals