A. Hardware test -common errors
C10F02 -Test returned with an error. No valid test results available
C10F07-Test function reported an unkown error
C10F18-Test timed out. No valid test results available
B. Hardware test -Power supply voltage
C10800
C10801
C10804
If the line voltage is below or above a limit the error code is displayed.
C. Hardware test -5V line
C10810
C10811
If the 5V voltage is below or above a limit the error code is displayed.
D. Hardware test -Current of optoelectronic LED
C10705
C10706
C10707
C10708
If the current / voltage is below or above a limit the error code is displayed.
E. Hardware test -Transducer signals
C10410
C10420
C10430
Checks transimpedance and signal amplifiers and transducer values. If no signals from the transducers
are detected the error code is displayed.
F. Hardware test -Auto stop system
C10380
C10381
C10382
C10383
Checks voltage on capacitor of the auto stop system.
If the voltage is below or above a limit or the recharging time is above a limit the error code is displayed.
14. Hardware test disturbed H 82
15. Power clamp service interval expired E93