Page 36
11.0 MAINTENANCE
BEFORE ANY MAINTENANCE OR REPAIRS ARE ATTEMPTED THE MACHINE MUST BE DIS-
CONNECTED FROM THE ELECTRIC SUPPLY.
This balancer does not require any special maintenance, but the following precautions are required:
A. Periodically clean all plastic parts with a glass cleaner. Wipe with a dry cloth.
B. Clean all adapters regularly with a nonflammable liquid detergent all. Lubricate with a thin layer of oil.
C. Periodically perform a routine shaft calibration as outlined on page 24 of this manual.
12.0 TROUBLE SHOOTING
TROUBLE CAUSE REMEDY
When turning the machine on, No electric power Check the input voltage
the displays do not light Defect in the electric/electronic system Call the Equiserv service center
for assistance
The machine gives random readouts. Machine unstable on the floor Check that machine is stable
Water in the tire Remove water from tire.
Loose adaptor Tighten the adaptor firmly
Defective electronic board Call the Equiserv service center
for assistance
The machine does not stop after Defective electronic component Stop using the machine immedi
balancing cycle ately and call the Equiserv service
center for assistance
The balancer is slow to display when This machine performs a self-test routine This is a normal characteristic
powering machine up. on start-up. There will be a delay of several of the machine
seconds before the display is activated.
If the balancer ceases to Malfunction of one of the scanners, Call the Equiserv service center
properly measure parameter A failure of the AWP system, for assistance
values or harness connection failure.