RXF ROTARY SCREW COMPRESSOR UNITS
FORMS
070.410-IOM (JAN 12)
Page 57
Page 3 Unit Serial # _____________________________ Frick Order No: ____________________________
Compressor Motor Setpoints and Information
Motor Name Plate VFD Manufacturer ________________
Motor Amps ___________ Maximum Drive Output ___ % Frame Size ______________
Volts ___________ Minimum Drive Output ___ % H.P. ____________________
Service Factor ___________ Remote Control RPM ___________________
Horsepower ___________ Rate Of Increase ________ % Delay ____ Sec Serial # _________________
CT Factor ___________ Rate Of Decrease _______ % Delay ____ Sec Service Factor ___________
__________ Min Capacity Control Voltage _________________
High Motor Amps When Slide Valve Reaches ________ % Hz _____________________
Load Inhibit______________ Drive Speed Reaches ________ % Design _________________
Force Unload__________ Variable Speed Min. Slide Valve Position _______ % Code ___________________
Warning________ Delay ___ Sec Skip Frequency Bands Bearing Type ________________
Shutdown________ Delay ___ Sec Bottom Top Motor Coupling _____________
_______ ______
Low Motor Amps _______ ______
Shut Down ________ Delay ______ Sec _______ ______
Conrmed Running Motor Amps _______ _______ ______
Starting Motor Amps Ignore Period ________ Sec _______ ______
Vyper Coolant Setpoints
Vyper Standby Time ______ Vyper Coolant Low Temp. Alarm______ Delay ______ Shutdown ______ Delay ________
High Temp. Alarm______ Delay ______ Shutdown ______ Delay ________
PHD Monitoring Setpoints Condenser Control
Compressor Bearing ____________ Condenser Control Setpoint _____________
Suction End Delay Discharge End Delay Digital Controls Step Order
High Warning ______ gF _____ Sec High Warning _____ gF _____ Sec Module A ________
High Shutdown ____ gF _____ Sec High Shutdown ____ gF _____ Sec Module B ________
Module C ________
Motor Bearing ______________ Module D ________
Shaft Side Delay Opposite Shaft Side Delay Step Up Dead Band _________PSI
High Warning _______ F _____ Sec High Warning ______ F _____ Sec Step Up Delay ________ Sec
High Shutdown _____ F _____ Sec High Shutdown _____ F _____ Sec Step Down Dead Band _________PSI
Step Down Delay ________ Sec
Motor Stator _________________ High Pressure Override _________PSI
High Pressure Override Delay _____ Sec
Stator 1 Delay Stator 2 Delay
High Warning ______F ______ Sec High Warning _____F ______ Sec Analog Controls Analog Output A ___________
High Shutdown ____F ______ Sec High Shutdown ____F ______ Sec Analog Output B ___________
Proportional Band ________PSI
Stator 3 Delay Integration Time _______ Sec
High Warning ______F ______ Sec High Limit ________PSI
High Shutdown ____F ______ Sec Low Limit _______ Sec
Miscellaneous
Remote Capacity Deadband _______ % Max Slide Valve Timer _______ 1/10 Sec
High Compressor Oil Pressure ________________ Max Discharge Pressure ___________PSI
Shutdown _____PSI Delay ____ Sec Max Discharge and Oil Temp ________°F