RXF ROTARY SCREW COMPRESSOR UNITS
FORMS
070.410-IOM (JAN 12)
Page 57
Page 3 Unit Serial # _____________________________ Frick Order No: ____________________________
Compressor Motor Setpoints and Information
Motor Name Plate VFD Manufacturer ________________
Motor Amps ___________ Maximum Drive Output ___ % Frame Size ______________
Volts ___________ Minimum Drive Output ___ % H.P. ____________________
Service Factor ___________ Remote Control RPM ___________________
Horsepower ___________ Rate Of Increase ________ % Delay ____ Sec Serial # _________________
CT Factor ___________ Rate Of Decrease _______ % Delay ____ Sec Service Factor ___________
 __________ Min Capacity Control Voltage _________________
High Motor Amps When Slide Valve Reaches ________ % Hz _____________________
Load Inhibit______________ Drive Speed Reaches ________ % Design _________________
Force Unload__________ Variable Speed Min. Slide Valve Position _______ % Code ___________________
Warning________ Delay ___ Sec Skip Frequency Bands Bearing Type ________________
Shutdown________ Delay ___ Sec Bottom Top Motor Coupling _____________
_______ ______
Low Motor Amps _______ ______
Shut Down ________ Delay ______ Sec _______ ______
Conrmed Running Motor Amps _______ _______ ______
Starting Motor Amps Ignore Period ________ Sec _______ ______
Vyper Coolant Setpoints
Vyper Standby Time ______ Vyper Coolant Low Temp. Alarm______ Delay ______ Shutdown ______ Delay ________
High Temp. Alarm______ Delay ______ Shutdown ______ Delay ________
PHD Monitoring Setpoints Condenser Control
Compressor Bearing ____________ Condenser Control Setpoint _____________
Suction End Delay Discharge End Delay Digital Controls Step Order
High Warning ______ gF _____ Sec High Warning _____ gF _____ Sec Module A ________
High Shutdown ____ gF _____ Sec High Shutdown ____ gF _____ Sec Module B ________
Module C ________
Motor Bearing ______________ Module D ________
Shaft Side Delay Opposite Shaft Side Delay Step Up Dead Band _________PSI
High Warning _______ F _____ Sec High Warning ______ F _____ Sec Step Up Delay ________ Sec
High Shutdown _____ F _____ Sec High Shutdown _____ F _____ Sec Step Down Dead Band _________PSI
Step Down Delay ________ Sec
Motor Stator _________________ High Pressure Override _________PSI
High Pressure Override Delay _____ Sec
Stator 1 Delay Stator 2 Delay
High Warning ______F ______ Sec High Warning _____F ______ Sec Analog Controls Analog Output A ___________
High Shutdown ____F ______ Sec High Shutdown ____F ______ Sec Analog Output B ___________
Proportional Band ________PSI
Stator 3 Delay Integration Time _______ Sec
High Warning ______F ______ Sec High Limit ________PSI
High Shutdown ____F ______ Sec Low Limit _______ Sec
Miscellaneous
Remote Capacity Deadband _______ % Max Slide Valve Timer _______ 1/10 Sec
High Compressor Oil Pressure ________________ Max Discharge Pressure ___________PSI
Shutdown _____PSI Delay ____ Sec Max Discharge and Oil Temp ________°F

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Johnson Controls Frick RXF 101 and is the answer not in the manual?

Johnson Controls Frick RXF 101 Specifications

General IconGeneral
BrandJohnson Controls
ModelFrick RXF 101
CategoryAir Compressor
LanguageEnglish

Related product manuals