Table 22: Mounting accessories
Product code Product description
BKT287-1R DIN rail; 0.30m or 12in.
BKT287-4R DIN rail; 0.36m or 14in.
PLT344-1R Two DIN rail end clamps
WHA-C450-100C System 450 module connection extension cable, 1m or 3.3ft long
Table 23: A99 Series temperature sensors
Product code Description
A99BA-200C Positive temperature coefficient (PTC) silicon sensor with shielded cable; cable length 2 m or 6.50 ft
Sensor temperature range: -40°C to 120°C or -40°F to 250°F
Cable jacket temperature range: -40°C to 100°C or -40°F to 212°F
A99BB-25C PTC silicon sensor with polyvinyl chloride (PVC) cable; cable length 0.25 m or 9.75 in.
Sensor temperature range: -40°C to 120°C or-40°F to 250°F.
Cable jacket temperature range: -40°C to 100°C or -40°F to 212°F.
A99BB-200C PTC silicon sensor with PVC cable; cable length 2 m or 6.50 ft
Sensor temperature range: -40°C to 120°C or -40°F to 250°F
Cable jacket temperature range: -40°C to 100°C or -40°F to 212°F
A99BB-300C PTC silicon sensor with PVC cable; cable length 3 m or 9.75 ft
Sensor temperature range: -40°C to 120°C or -40°F to 250°F
Cable jacket temperature range: -40°C to 100°C or -40°F to 212°F
A99BB-500C PTC silicon sensor with PVC cable; cable length 5 m or 16.38 ft
Sensor temperature range: -40°C to 120°C or -40°F to 250°F
Cable jacket temperature range: -40°C to 100°C or -40°F to 212°F
A99BB-600C PTC silicon sensor with PVC cable; cable length 6 m or 19.50 ft
Sensor temperature range: -40°C to 120°C or -40°F to 250°F
Cable jacket temperature range: -40°C to 100°C or -40°F to 212°F
A99BC-25C PTC silicon sensor with high temperature silicon cable; cable length 0.25 m or 9.75 in.
Sensor temperature range: -40°C to 120°C or -40°F to 250°F
Cable jacket rated for full sensor temperature range
A99BC-300C PTC silicon sensor with high temperature silicon cable; cable length 3 m or 9.75 ft
Sensor temperature range: -40°C to 120°C or -40°F to 250°F
Cable jacket rated for full sensor temperature range
A99BC-1500C PTC silicon sensor with high temperature silicon cable; cable length 15 m or 49 ft
Sensor temperature range: -40°C to 120°C or -40°F to 250°F
Cable jacket rated for full sensor temperature range
A99-CLP-1 Mounting clip for A99 temperature sensor
Note: For more information, refer to the A99B Series Temperature Sensors Product/Technical
Bulletin (LIT-125186).
Table 24: P499 Series transducers with 1/4 in. SAE 45 flare internal thread with depressor
(Style 47)
Product code Description
P499RCPS100C -10 psis to 100 psis, sealed for wet, freeze and thaw applications; order WHA-PKD3 type wire harness
separately.
P499RCPS100K -10 psis to 100 psis, sealed for wet, freeze and thaw applications; WHA-PKD3-200C wire harness
included.
P499RCPS102C 0 psis to 200 psis, sealed for wet, freeze and thaw applications; order a WHA-PKD3 type wire harness
separately.
P499RCPS102K 0 psis to 200 psis, sealed for wet, freeze and thaw applications; WHA-PKD3-200C wire harness
included.
P499RCP-101C 0 psig to 100 psig; order a WHA-PKD3 type wire harness separately.
System 450 Series C450CCU Condensing Unit Control System Technical Bulletin40