Incline function does not work
Possible causes:
1. The 8-pin console cable is damaged.
2. Incline motor is damaged.
3. PCB is damaged.
4. MCB is damaged.
5. The incline setting is not correct.
Fix:
Enter to the Engineering Mode to recalibrate the elevation values
Then press "FAST" and "SLOW" key to see if the incline motor will be
activated.
1. OR
Use a new 8-pin console cable to connect PCB and MCB. Then press
"FAST" and "SLOW" key to see if the incline motor will be activated.
2. OR
Replace the incline motor.
3. OR
Replace PCB.
4. OR
Replace MCB.
5. Enter Engineering Mode to reset the elevation parameter.