6019-025
Fitting the Hydrostatic Transmission Cable
Repair Instructions
Screw in the forward link joint on the new hydro-
static transmission cable and tighten the lock nut.
Run the cable through the rider so that it follows the
same path as the old cable did.
Press in the cable casing in the forward fastener in
the centre console.
Tighten the hydrostatic transmission cable in place.
Press the link joint onto its fastener and attach the
spring lock.
Attach the link joint to the lower part of the hydro-
static transmission cable. Screw 10-12 turns so that
the link joint has the right length.