28
5.6.1 Working Mode Setting (L1)
Due to the usage for this product is different for users from different regions, the control board for
this product offers 3 different working modes for users to choose.
1. Standard Mode (L1):
Terminals for external buttons:
OSC: Single button control PED: Pedestrian button STP: Stop button
2. Three Button Mode (L2):
Terminals for external buttons:
OSC: Opening button PED: Closing button STP: Stop button
3. Community Mode (L3):
Terminals for external buttons:
OSC: Single button control PED: Pedestrian button STP: Stop button
Special function: Only the door is fully opened, can it be closed thereafter. If the door is not fully
opened, then only opening and stop can be operated in order to prevent any interruption which will
trigger closing during the opening travel operated by the first user.
A. Operation Instruction:
1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0 will flicker
once, then L1 will be always on.
2. Press “PROG” button again for 3 sec. to enter into advanced menu. Indicator light L0 will
flicker twice, then L1 will be always on.
3. Press “SET” button once to enter into working mode setting option. Indicator lights L1-L3 will
show the current setting. (The default is L1)
4. Press “+” or “-” button to set the working mode. Indicator lights L1-L3 will show the setting.
5. Press” SET” button once to save and automatically exit. Indicator lights L1-L5 will be on for
one sec.