29
B. Operation Graphic Illustration
Press "PROG" button for 3 sec
LED
PROG
L0 flicker once, L1 will be on
LED
SET
LED
Press "PROG" button again
PROG
LED
L0 will flicker twice,L1 will be on
SET
Press "SET" button once
for 3 sec
Press "+" or "—" button to adjust the
parameters, LED will show the
corresponding value
Press "SET" button once
L1-L5 will be on for one sec
Save and exit automatically
Figure 30
5.6.2 Acceleration Setting (L2)
Due to the different installation environment and gate installation status, users can adjust the
acceleration of starting and deceleration of buffering of the gate opener to their necessary.
A. Operation Instruction:
1. Press and hold “PROG” button for 3 sec. to enter into basic menu. Indicator light L0 will flicker
once, then L1 will be always on.
2. Press “PROG” button again for 3 sec. to enter into advanced menu. Indicator light L0 will
flicker twice, then L1 will be always on.
3. Press “+” button once to select acceleration setting option. Indicator light L2 will be always on.
4. Press “SET” button once to enter into acceleration setting. Indicator lights L1-L5 will show the
current acceleration. (The default is L3)
5. Press “+” or “-” button to set the acceleration. Indicator lights L1-L5 will indicate the different
accelerations. The more the indicator lights will be on, the faster the speed changes.
6. Press” SET” button once to save and automatically exit. Indicator lights L1-L5 will be on for
one sec.