EasyManua.ls Logo

JRC JCY-1800 - NMEA Monitor Operation

JRC JCY-1800
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5. Instruction
JCY-1800/1850 VDR/S-VDR Installation Guide
94
DOC No. 7ZPJD0387C
5.2. Operation Panel Unit (NCG-169)
5.2.1. Names and functions of each part of the External Operation Board
7) HEADING LED
8) ALARM DETAIL LED
1) POWER LED 9) MODE SWITCH
2) RECORDING LED 10) ERROR CODE LED
3) ALARM LED
11) CURSOR SWITCH
5) ALARM ACK SWITCH
12) ENTER SWITCH
4) DIMMER SWITCH
6) ALARM BUZZER
Figure 5-5: Operation Panel Unit
Table 5-5: Names and Functions of the Operation Panel Unit
No. Names and Functions
1)
POWER LED:
Lights when the Recording Control Unit is in normal operation with the power supplied from outside.
Blinks when there is a blackout during the operation. If the blackout lasts, it turns off in 2 hours.
(automatic shutdown)
2)
RECORDING LED:
Lights when the output data from the Recording Control Unit is recorded into the Protective Capsule
Unit.
3)
ALARM LED:
Blinks when an error(s) is (are) detected in the S-VDR. Pressing the ALARM ACK SWITCH changes it
from blinking to lighting.
It is turned off when all the errors detected are restored to normal.
4)
DIMMER SWITCH:
Controls the brightness. Press the switch then the brightness changes cyclically.
5)
ALARM ACK SWITCH:
Used to stop the ALARM BUZZER. When more than one error is detected, press the switch as many times
as the errors arose.
6)
ALARM BUZZER:
Sounds when an error is detected in the S-VDR. To stop press the ALARM ACK SWITCH.
7)
HEADING LED:
Lights when the Operation Panel Unit is operated in NSK mode.
The HEADING LED blinks when the initial value of heading is not registered.
The NSK mode is usable when the NSK-I/F Board is activated.
If the NSK-I/F Board is not activated, the HEADING LED is turned off all the time.
8)
ALARM DETAIL LED:
Lights when the Operation Panel Unit is operated in normal mode.
The ALARM DETAIL LED is always on as long as S-VDR is operated without any problem.
NCG-169 VDR OPERATION PANEL
POWE
RECORDING
ALARM
ACK DI
HEADING
ALARM DETAIL
SYSTEM
CODE
MODE
ENT

Table of Contents

Other manuals for JRC JCY-1800

Related product manuals