6. Setting
JCY-1800/1850 VDR/S-VDR Installation Guide
101
DOC No. 7ZPJD0387C
6.4. Main Control Board (CDJ-2304) /(RMB: CDK-287) DIP-SW setting
Change a setup of DIP-SW if needed after understanding the purpose of a facility enough.
Initial states are all the switches OFF.
(The * is marked to the switch which can use in the CDK-287..)
CONF Function Setting Remark
0 * EEPROM Initialize a configuration data in EEPROM.
OFF: not initialize
ON: Initialize by both of switches 0 and 4 are ON
Be sure to return to OFF after
initialization.
1 Radar image error Alarm as no image signal
OFF: Activate an alarm at receiving no image signal
ON: Inhibit an alarm
Turn ON to inhibit an alarm
by turning off Radar.
2 Both radar image error Alarm as no image signal from both channel
OFF: Activate an alarm at receiving no image signal
from both channels.
ON: Activate an alarm at receiving no image signal
from any channel.
Turn ON the switch 1 to
alarm.
3 SPARE
4 * EEPROM Initialize a configuration data in EEPROM.
OFF: not initialize
ON: Initialize by both of switches 0 and 4 are ON
Be sure to return to OFF after
initialization.
5 CF Card release Waiting time to release the card
OFF: 5 seconds
ON: 60 seconds
Choose 60 seconds mode to
record the last 1minutes data.
6 CF Card format Formatting CF card
OFF: Card is formatted, when abnormalities are
detected on card format at startup.
ON: Card is formatted at startup.
7 * Safe mode Maintenance mode for MCB
OFF: Normal mode
ON: Safe mode
Don't change
CONF DIP-SW