EasyManua.ls Logo

JRC JCY-1800 - Cabling of the Digital Signal Converter NCT-72; 63 (VDR Option)

JRC JCY-1800
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Cabling
JCY-1800/1850 VDR/S-VDR Installation Guide
76
DOC No. 7ZPJD0387C
4.3. Cabling of the Digital Signal Converter NCT-72 / 63 (VDR option)
The following cables are connected to the Digital Signal Converter (DSC).
1) A data cable between Non voltage Digital Signal Converters and the DSC
2) A serial data cable between the DSC and the RCU
3) Power Supply cable
4.3.1. Digital Signal Converter NCT-72/63 – Dry contacts output Equipments
The Digital Signal Converters are connected to sensors that output dry contact signals.
NCT-72 has 64 ports for inputting Dry contact data.
• NCT-63 has 16 ports for inputting Dry Contact data. (not installed TB2, 3, 4)
Connection table for sensors: ch1 ~ ch16 (NCT-72 and NCT-63)
DSC
Term #
Sensor
Term #
Signal Name
CQD-2081/2012
TB1 [CH-1 to 16]
1/3/5/7/9/11/13/15/17/19/21/2
3/25/27/29/31 [IN+]
OUT+ Dry Contact Signal:
2/4/6/8/10/12/14/16/18/20/22/
24/26/28/30/32 [IN-]
OUT- Dry Contact Signal:
[IN-] line is commonly shared by all.
Cable Cramp SHIELD SHIELD
Connection table for sensors: ch17 ~ ch32 (NCT-72 only)
DSC
Term #
Sensor
Term #
Signal Name
CQD-2081/2012
TB2 [CH-17 to 32]
31/29/27/25/23/21/19/17/15/13
/11/9/7/5/3/1 [IN+]
OUT+ Dry Contact Signal:
32/30/28/26/24/22/20/18/16/14
/12/10/8/6/4/2 [IN-]
OUT- Dry Contact Signal:
[IN-] line is commonly shared by all.
Cable Cramp SHIELD SHIELD
Connection table for sensors: ch33 ~ ch48 (NCT-72 only)
DSC
Term #
Sensor
Term #
Signal Name
CQD-2081/2012
TB3 [CH-33 to 48]
1/3/5/7/9/11/13/15/17/19/21/2
3/25/27/29/31 [IN+]
OUT+ Dry Contact Signal:
2/4/6/8/10/12/14/16/18/20/22/
24/26/28/30/32 [IN-]
OUT- Dry Contact Signal:
[IN-] line is commonly shared by all.
Cable Cramp SHIELD SHIELD