4. Installation, Setup and Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
11
DOC No. 7ZPNA4014
4.1.2. Operating procedure for installation
Set up and check the VDR/S-VDR on the “SYSTEM” screen as following procedure.
The “Report” folder is created on the Desktop of PC automatically.
Compress this folder, and upload the compressed files to the “Ship list” on the Marine service WEB.
Step Item Operation Contents See
1
Receive a system
configuration data
Receive button
The Maintenance software receives a system
configuration data from the RCU.
Click the [Receive] button.
Setup information is displayed on the System screen
after receiving.
4.2.1
2 Set each connection Check box for connection
Enter the check mark into the check box of each
connection channel and each configuration unit with
reference to an Installation drawing.
4.3.1
4.4.1
4.5.1
4.6.1
4.7.1
4.8.1
3 Set a detail information Detail button
Click the Detail button of the section to set up.
Select the connection channel in sensor section before
clicking the Detail button.
4
Transmit a system
configuration data to
the RCU
Set button in each detail
window
Click the Set button in the detail window after entering
all data.
5 Set up the System
Repeat the Step3 and
Step4
Enter the detail information data of all section and
each channel of the Sensor section.
4.3.2
4.4.2
4.5.2
4.6.2
4.7.2
4.8.2
6 Reboot the RCU Reboot button
Click the Reboot button on the System screen.
The RCU is operated by renewed system configuration
data, after rebooting.
Check the diagnostic
results
Diagnosis button and
lamp
Click the Diagnosis button on the System screen.
Maintenance software shows the diagnostic results by
color of each lamp.
Check the color of diagnostic lamp, green lamp means
OK.
5
7
Receiving data Real time monitor Check a receiving data by the real time monitor.
7
8
Improve, if there is a
problem.
Return the STEP3
The red and yellow color of lamp means the problem
of setup, wiring or connection equipments.
Improve the problem shown by the Maintenance
software.
The orange color of lamp means under diagnosis.
9 Recorded data Playback Check a recorded data by the Playback software.
10
10 Complete the setup
All diagnostic lamp of
System screen
Make all lamps green and complete a setup.
5
11 Make the report Report A report files are created.
13