11. Frame Grabber Board (CKA-137) setup - FGB utility -
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
121
DOC No. 7ZPNA4014
11. Frame Grabber Board (CKA-137) setup - FGB utility -
“FGB_Utility” software is useful for setup and tuning the Frame Grabber Board CKA-129/CKA-137. The setup menu
contain that the capture setup file and other file set the board. The tuning menu contains that sync polarity tuning,
horizontal/vertical position tuning, and sampling phase tuning.
11.1. Check the Radar image specifications
For proper capture setting, check the Radar image specifications (VESA format only). Check the item as
bellow.
Resolution: (ex. 1280x1024)
Vertical synchronous signal frequency (Refresh rate): (ex. 60 Hz)
Horizontal synchronous signal frequency: (ex. 75 kHz)
Vertical synchronous signal polarity: (ex. Positive or Negative)
Horizontal synchronous signal polarity: (ex. Positive or Negative)
11.2. Setup & Capture
11.2.1. Start the "FGB Utility" program
Click the “FGB Utility” from System menu of the VDR/S-VDR Maintenance Software.