4. Installation, Setup and Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
22
DOC No. 7ZPNA4014
4.3.4.3. Checking setup data
Confirm that there is no blank in setting data.
Defect in setting entry (Model, Serial number, etc.) as warning can be displayed to the
“Entry” lamp.
(Green): All entries are inputted.
(Yellow): The blank entry remains.
Look for a blank entry and input a setup data to blank entry.
4.3.4.4. Transmitting setup data
Transmit the setup data to the RCU.
Transmit
Click the [SET] button.
Cancel
Click the [Close] button.
4.3.4.5. Real Time Monitor
Monitor the NMEA sentence data which is collected in the RCU on real time, and check the sentence specified by the
installation drawings is collected correctly.
1) Procedures
START: Click the [Start] button.
* Real time monitor is automatically started at the opening window.
STOP: Click the [Stop] button.
2) Selecting the monitor data type.
Click the radio button of data type (“RCV Data” /”REC Data”) to monitor.
“RCV Data”: Monitors all data which the RCU receives.
The sentence data which is not recorded on the VDR/S-VDR is also displayed.
REC data: Monitors the sentence data which is recorded in the VDR/S-VDR.
The sentence which is not recorded is not displayed even if it has received.
The monitor data is displayed by the sentence format currently recorded in the VDR/S-VDR.