2.10 Connecting the Remote Controller (NCH-466E)
The JFV-700/HP accepts connection of the optional remote controller.
The remote controller allows you to record or reproduce the screen data, and generating
the water temperature and the water depth alarms.
Connecting procedure:
Connect to the connector to J902.
External view of the remote controller
2.11 Actions Required After the Installation
1. After the set has been installed, turn on power for every equipment on the boat to
make sure that the set may not adversely affect them, or vice versa.
2. Performance of the set can be affected by engine noise. Increase the engine
revolution to the level employed in normal operations to make sure that the set is
immune from the noise.
3. The set can generate noise on the radio equipment. If such trouble is seen, refer to
Section 2.13 to develop appropriate measures.
2.12 Actions Taken for Noise Trouble
Actions to be taken vary depending on how the set is installed and used on a given boat.
Thus, the following is examples of the measures offered for your consideration.
(1) Noise on the Power Cable and Transducer Cable
Shield the power cable and piezoelectric transducer cable. Wrap a piece of copper
foil (Code: 5ZZKG00004) to the cable, then connect one end of the cable to the con-
nector fitting and the other end to the grounding cable.