37
2. When 200 kHz is selected, the following modification is required.
200 kHz is output to the 5-pin connector (J905 A/B or A). Direct the output to the 3-in
connector (J906 “B”) by the following modification.
Remove P701 and P702, then insert P106 to the once P105 position and insert P105
to the once P106 position.
3. Change the JP701 to JP704 according to Table 4.1 in page 41.
When changing, Both JP701 and JP702, JP03 and JP704 must be changed at the
same time.
4. Apply the master reset.
For this operation, refer to the “Implementing the Master Reset” in Section 4.3 in page
42.
J701 and J702 Positions (for 7PCBS7035)
J701 and J702 Positions (for 7PCBS7035A)
J702 J701
J702
J701