6-15 
 
 
6.5.1 DC12/24V DATA connector 
 
 
 
 
 
 
     
     
     
     
        
     
     
     
     
     
     
 
      Display Unit Rear     
 
 
 
 
 
 
 
 
 
Terminal Number 
(CFQ-5766) 
Name  Explanation 
1 Red 
DC12/24V 
DCIN +  Connect the accessory power cable.   
The power-supply voltage range is 10.8 to 31.2 VDC. 
When you use the old GPS sensor (except JLR-4341 or 
JLR-4340), the power voltage is Only 12VDC. (GPS) 
2 Black  DCIN - 
3 Orange 
Contact 
Output 
ALM_COM
Output contact signals 
 
4 Yellow  ALM_NO 
5 Green  ALM_NC 
6 Blue  Contact 
Input 
Analog Input 
ACK_IN+ 
Input contact signal or external dimmer. 
 
7 Purple  ACK_IN- 
8 Gray Serial 
Transmission 
(DATA I/O 1) 
SD0-A  Input and output to the specifications set by “DATA 
IN/OUT1.” 
 
9 White  SD0-B 
10 Pink  Serial 
Transmission 
(DATA I/O 2) 
SD3-A  Input and output to the specifications set by “DATA 
IN/OUT2.” 
 
11 Sky blue  SD3-B 
12 Bright 
green 
Serial 
Transmission 
(DATA I/O 3) 
SD6-A 
Input and output to the specifications set by “DATA 
IN/OUT3.” 
 
13 Brown  SD6-B 
14 Black 
(Shield) 
Chassis 
Earth 
E 
Chassis earth 
 
To connect the Doppler Log, refer to "SERVIC MANUAL" or "INSTALLATION MANUAL" of the 
Doppler Log (JLN-205MK2). 
CFQ5766
1A
1A
+
-
Red
Black
Fuse Holder 
Containin
 1A Fuses
Data Power Cable 
CFQ-5766A:  2 m (Accessory) 
CFQ-5766D:  10 m (Option) 
CFQ-5766F:  20 m (Option) 
  14  13 
   12  11  10 
 9  8   7   6 
   5   4   3 
     2   1 
Display Unit Rear:   
Connector Pin Number 
Warning of GPS sensor connection 
In this display, the voltage supplied to the display is supplied to a receiver as it is.   
When you use receivers except JLR-4341/JLR-4340, set the power supply of a display to 
DC12V. Supply of 24V will damage a receiver.