Section 17 Setting up Alerts 17-2
The [Alert] dialog box consists of the classification pane and the edit pane.
By clicking the Disclosure button ( ), you can hide the classification pane. To show the
classification pane again, click the Disclosure button ( ).
17.1.2 Selecting a setting item
1 Click the alert classification you want to set up in the classification pane.
The setting dialog of the selected item is displayed in the edit pane.
2 Set up in the edit pane.
The following items can be set in the [Alert] dialog box.
Setting item
Setting contents
Function restriction
Collision Avoidance Set the following conditions to generate a collision
avoidance alert.
CPA/TCPA limit value
Status of the AIS target to be targeted for a lost
alarm
Refer to "17.2
Collision Avoidance Alert
Generation Conditions".
New Target Warning Set the following conditions to generate an
automatic acquisition target alarm.
Area (AZ) for TT target automatic acquisition
Enable/disable AZ
Refer to "17.3
New Target Warning Generation
Conditions".
Depth/Safety
Contour
Set the following conditions to generate a
grounding avoidance alert.
Safety contour line approach alarm
Refer to "17.4 Depth/Safety Contour Alert
Generation Conditions".
The "Safety contour
line approach alarm"
can also be set on the
ECDIS screen and the
chart radar screen
(when the chart option
is set for the radar as
chart display option).
Look-ahead (Forward
forecast monitoring)
Set a forward forecast monitoring
Refer to "17.5 Setting Up Look-ahead".
ECDIS screen and
chart radar screen
(when the chart option
is set for the radar as
chart display option)