EasyManua.ls Logo

JS-AZ PRIS SCALE - RS-232 Data Variables

JS-AZ PRIS SCALE
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
33
.
TOTAL
Net 05000.0 g
Pcs 000000
Net=Net Weight Pcs=Quantity U/W=Unit Weight
4. Variables (The prompt character) used in scale also in label
printer.
Variable Name Specifications Size
SER Accumulated times 2 byte
NWA Net weight 7 byte
NWB Net weight(no dot) 6 byte
TWA Tare weight 7 byte
TWB Tare weight (no dot) 6 byte
GWA Gross weight 7 byte
GWB Gross weight (no dot) 6 byte
TNA Total net weight 7 byte
TNB Total net weight(no dot) 6 byte
TTA Total Tare weight 7 byte
TTB Total Tare weight (no dot) 6 byte
TGA Total Gross weight 7 byte
TGB Total Gross weight(no dot) 6 byte
UWA Unit weight 7 byte
UWB Unit weight (no dot) 6 byte
QUA Quantity 7 byte
QUB Quantity (no dot) 6 byte
TQA Total Quantity 7 byte
TQB Total Quantity (no dot) 6 byte
UNT Weighing Unit 2 byte
Note: 1) Capital Letters are allowed for the Variable Name only. Users
are not supposed to change them; otherwise they won’t be
supported in transmitting process.
2) Please refer to the manual operation of the label printer for
exact use.