ā 136 ā
(2) Display the pedal customize screen.
When the mode changeover key is kept pressed
for 3 seconds, the pedal customize button C
displayed on the screen changes color from green
to light blue. When this button is pressed, the pedal
customize screen of the maintenance personnel level
is displayed.
C
(3) When the foot pedal adjustment button D
is pressed, the foot pedal adjustment screen is
displayed. Set up the number of steps corresponding
to the pedal tread-on amount.
(4) The volume bar display E indicates the voltage value
of the pedal sensor in the present state of pedal
treading-on within the data range of 0 to 99.
In the first place, in the state that the pedal is reversely
trodden on, press the reverse tread-on input button
F. The voltage value at that time is then entered in G.
Then, press the free input button H in the pedal free
state. The voltage value at that time is then entered
in I. In the similar manner, make the setting of step J
for step advancement.
(Reference) 1. When the F, G, H buttons are pressed
directly, a ten-key input screen is
displayed. Then direct numerical input
entry becomes possible.
2. Only in the case of reference one-shot
pedal, reverse pedal treading-on may
be performed to set up H. Then, the
pedal is trodden on to set up D. In this
manner, the steps can be advanced by
depressing the back part of the pedal.
This setting is convenient for the work
in standing posture.
D
F
H
G
I
E
K
J