Change-over of the position of clamp foot after sewing end - - - - - -
Position of clamp foot after sewing end is selected from Stop at front end/
Return to medium/Clamp return/Stop at rear end.
Stop at front end Return to medium
Clamp return Stop at rear end
Front end motion start waiting time 0.00 to 9.99 3.00 sec.
Waiting time up to the start of front end motion of clamp foot is set. /
* It is possible to set only when is set to the stop at front end. 0.01 sec.
Number of times of feeding of automatic interlining supplying at sewing start 2 to 9 3
Number of times of feeding of automatic interlining supplying device at /
sewing start is set. 1
* It is possible to set only when automatic interlining supplying
option is used.
Feeding length of automatic interlining supplying at sewing end 0 to 99.9 0mm
Feeding length of automatic interlining supplying device at sewing end is set. /
* It is possible to set only when automatic interlining supplying 0.1mm
device is used.
Thread trimming timing - - -
Thread trimming timing after sewing is selected from Standard/ Medium/
Longest and length of thread at sewing end is adjusted
Standard 0 Medium 1
Longest 2
* When and zipper device are mounted setting is “0”, needle
thread may not be trimmed.
Stacker timer 2 0.00 to 9.99 0.70 sec.
Waiting time from the start of clamp motion to hold material on the stacker /
base to release the material presser is set. 0.01 sec.
* It is possible to set only when clamp bar stacker option is used.
Setting range
No. Item / Initial value
Edit unit
– 99 –
(3) Memory switch data list
• Level 1
Memory switch data (level 1) are the motion data the sewing machine has in common and the data that operate on
all sewing patterns in common.
......... Item that is not displayed due to other setting start.