– 143 –
(3) Description of dip switches
1) MAIN board dip switch
The dip switch on the MAIN board is used as a functional changeover switch for production.
No modification shall be carried out after shipment because all adjustments and other settings are definite and
unnecessary to be modified.
(Caution) All setup values at the time of shipment are based on the OFF condition.
2) SDC board dip switch
The two dip switches on the SDC board are used as the functional changeover switches for production.
No modification shall be carried out after shipment because all adjustments and other settings are definite and
unnecessary to be modified.
(Caution) All setup values at the time of shipment are based on the OFF condition.
3) PANEL board dip switch
The dip switch on the PANEL board is used as a functional changeover switch for production.
No modification shall be carried out after shipment because all adjustments and other settings are definite and
unnecessary to be modified.
(Caution) The setup values at the time of shipment are based on the ON condition for 1 and 2, and OFF
condition for 3 and 4.
4) PMDC board dip switch (For roller stacker)
The dip switch on the PMDC board is used as a functional changeover switch.
No modification shall be carried out after shipment because all adjustments and other settings are definite and
unnecessary to be modified.
The setup values at the time of shipment are based on the OFF condition for SW1-1 only, and ON condition for
SW1-2, -3, -4.
(Caution) Make all settings again because all the switches are set at OFF if the replacing PMDC board is
a newly purchased item.
SW Function
Motor driving system selection
SW1-1 OFF 1 : OFF•2 : OFF=1/8step
1 : ON •2 : OFF=1/4step
SW1-2 ON 1 : OFF•2 : ON =half step
1 : ON •2 : ON =full step
Selection of driving current
OFF=Standard ON=High current
Input selection
OFF=Standard ON=Board detection
SW1-3 ON
SW1-4 ON
(Caution) Stabilized operation is assured only for the definite
combinations of the setup conditions.
Those other than the above-mentioned combinations
shall not be used for the roller stacker.