EasyManuals Logo

JUKI LU-1508H Engineer's Manual

JUKI LU-1508H
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
−10
. Standard of the lower dead point of the needle bar
1. Set the stitch dial to “0” mm.
2. Turn the handwheel to bring needle bar to the lower dead
point of its stroke.
3. Loosen the setscrew in the face plate to remove the face
plate.
4. Loosen setscrew in the needle bar connection.
At this time, loosen the setscrew to such an extent that the
needle bar moves up or down by hand since the needle bar
drops if the setscrew is fully loosened.
5. Adjust the distance from the lower end of the needle bar frame
to the lower end of the needle bar to the dimension A, and
tighten the setscrew.
(For the LU-1510-7, there is an engraved marker line on the
needle bar.)
. Needle-to-blade point of hook timing
1. Set the stitch dial to “0” mm.
2. Turn the handwheel and loosen setscrew in the needle
bar connection to adjust so that a clearance of 1.5 mm is
provided between the top end of the needle eyelet of needle
and blade point of the hook when needle bar is raised
by 2.3 mm from the lower dead point of its stroke. Then, tighten
the setscrew again.
(For the LU-1510-7, there is an engraved marker line on the
needle bar.)
3. Turn the handwheel to make the needle bar ascend by 2.3
mm from the lower dead point of its stroke. Loosen two
setscrews in the screw gear (small) so that blade point
of the hook is almost aligned with the center of needle .
For the LU-1508H, however, 2.5 ± 0.3 mm instead of 2.3 mm
is applied.
4. Loosen setscrew in the hook shaft saddle and move the
hook shaft saddle to the right or left until a clearance of 0.05
to 0.15 mm is provided between the blade point of the hook
and the needle at the position where blade point of the
hook is almost aligned with the center of needle . After the
adjustment, tighten the setscrew.
5. Loosen two setscrews in the screw gear (large) and move
the screw gear (large) to the right or left until blade point of
the hook is aligned with the center of needle . After the
adjustment, tighten the setscrews.
6. Set the stitch dial at the maximum and check that the needle
and the blade point of the hook do not come in contact with
each other.
. Adjusting the hook needle guard
1. Bend hook needle guard to adjust so that the hook needle
guard pushes the side face of the needle to lean the needle
by 0.1 to 0.2 mm away from its straight position.
(Caution) After tightening the screw gears of the hook
shaft, check that there is no thrust play in the
hook shaft.
Check that there is a backlash in the screw
gears of the hook shaft.
Adjustment Procedures Results of Improper Adjustment

Table of Contents

Other manuals for JUKI LU-1508H

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JUKI LU-1508H and is the answer not in the manual?

JUKI LU-1508H Specifications

General IconGeneral
BrandJUKI
ModelLU-1508H
CategorySewing Machine
LanguageEnglish

Related product manuals