– 68 –
Error code Description of error Cause Item to be checked
E971 Protection of the cloth
puller motor against IPM
overcurrent
Cloth puller motor maloperation.
E972 Cloth puller presser motor
overload error
Load applied to the cloth puller
presser motor is excessively
large.
Check whether the cloth puller presser motor
runs smoothly.
E973 Protection of the cloth
puller motor against IPM
overcurrent
Cloth puller motor maloperation.
E974 Cloth puller motor over-
load error
Load applied to the cloth puller
motor is excessively large.
Check whether the feed driving motor runs
smoothly.
E975 Presser foot motor over-
current error
Presser motor maloperation.
E976 Presser foot motor over-
load
In the case the presser motor is
applied with an excessive load.
Check whether the presser motor runs
smoothly.
E977 CPU fault In the case the program is faulty.
E978 Network communication
fault
Data received from the network
has broken.
E985 Cloth puller presser motor
origin retrieval error
In the case the cloth puller
presser motor has failed to
travel to its origin.
Check whether the cloth puller presser motor
runs smoothly.
E999 Main software rewriting • In the case the software has
been rewritten.
This is not an error.