Installing the CTP150 Platform in Freestanding Mode
When installing the device on a table top or in any other freestanding mode, be sure to leave enough space
around the device for adequate ventilation. Position the chassis with easy access to the connections that
it needs for power, local communications, and remote communications.
WARNING: At least two people are required to lift the device. Three people are
required for the heavier CTP platforms.
CAUTION: To prevent electrostatic damage to the device and its components, make
sure that persons handling the device wear an antistatic device.
RELATED DOCUMENTATION
Before You Install the CTP150 Platform | 59
Installing the CTP150 Platform in a Rack | 60
Cabling the CTP150 Platform Overview | 69
Installing the CTP150 Platform in a Rack
To install the CTP platform in a rack, you need:
Phillips screwdriver
Four 10-32 x 3/8 Phillips screws for each device to be installed
Follow these guidelines:
1. Following your installation plan, use a tape measure and marking pen to measure and mark space on
each equipment rack for each platform component. For horizontal spacing, follow Network Equipment
Building System (NEBS) requirements.
2. With one person standing on the left side of the device and another standing on the right side, lift the
device into the rack.
60

Table of Contents

Other manuals for Juniper CTP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper CTP Series and is the answer not in the manual?

Juniper CTP Series Specifications

General IconGeneral
BrandJuniper
ModelCTP Series
CategoryServer
LanguageEnglish

Related product manuals