EasyManua.ls Logo

Juniper CTP2000 Series - CTP2024 Platform Specifications and Certification; Table 11: CTP2024 Platform Specifications

Juniper CTP2000 Series
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CTP2024 Platform Specifications and Certification
Table 11: CTP2024 Platform Specifications
SpecificationCategory
Weight
20 lb (9.07 kg)Chassis only
Dimensions
3.5 in. (8.89 cm) high
17.25 in. (43.81 cm) wide
11.25 in. (28.57 cm) deep
Chassis only
Environmental Requirements
32° to 104° F (0° to 40° C)Ambient operating temperature
5% to 90% (noncondensing)Ambient operating humidity
DC Input
–40 to 72 VDCVoltage
3A @ –48 VDCCurrent
144 WPower
2 independent line feedsRedundancy (input power)
AC Input
100–240 VACPower required
50–60 HzAC line frequency
2.0Nominal current (115V amps)
200 WPower
3 ft. (90 cm) behind device or rack.
Do not block air vents on the front or back of the device.
Space Requirements
Air intake occurs from the front of the device.
Air is exhausted out the back of the device.
Airflow
33Copyright © 2017, Juniper Networks, Inc.
Chapter 3: System Specifications

Table of Contents

Other manuals for Juniper CTP2000 Series

Related product manuals