5. Place the chassis grounding lug and cable over the PEM nuts with the cable connection pointing to the
left. See Figure 65 on page 162 and Figure 66 on page 162.
Figure 65: Connecting a Grounding Cable to the MX10008
Figure 66: Connecting a Grounding Cable to the MX10016
6. Place the two screws over the grounding lug and grounding cable.
7. Tighten the two 10-32 screws using a Phillips screwdriver applying torque between of 30.1 in.-lb (3.4
N-m) and 42.04 in.-lb (4.75 N-m).
8. Dress the grounding cable and ensure that it does not touch or block access to other device components
and that it does not drape where people could trip over it.
162