JVA ELECTRIC FENCE SYSTEMS
41
Standard Requirements
Figure 10 – Typical fence constructions where the electric security fence is
installed in windows and skylights
Note 2: Typical electric security fence installations are shown in Figure 9 and
Figure 10.
10.4.4 Separation between electric fence and physical barrier
Where a physical barrier is installed in compliance with 3 at least one dimension in
any opening should be not greater than 130 mm and the separation between the
electric fence and the physical barrier should be
one dimension in each opening in the physical barrier is not greater than 130
have any openings.
Note 1: These restrictions are intended to reduce the possibility of persons making
inadvertent contact with the pulsed conductors and to prevent them from
becoming wedged between the electric fence and the physical barrier,
thereby being exposed to multiple shocks from the energizer.
Note 2: The separation is the perpendicular distance between the electric fence and
the physical barrier.