4.1.4 Set up for adjustment
(1) Connect appropriate measuring instruments, jigs, and tools required for the adjustment item.
4.2 ADJUSTMENT
The adjustment for this model is a special adjustment using a
PC.
Use the self-diagnostic software SSS (Service Support System)
for adjustment.
4.2.1 Basic usage of the SSS for adjustment
(1) Click [Adjustment Utility] on the main screen of the SSS.
(2) The Adjustment Utility screen is displayed.
• The adjustment items are categorized into the following
six groups.
Click the tab on the Adjustment Utility screen to select.
1) Setting Serial No.
2) Deck Adjustment
3) Camera Adjustment
4) Optical Adjustment
5) Color View Finder (C.VF) Adjustment
6) ROIS Adjustment
(3) Select the item to adjust.
a) Click the [Procedure], then select the adjustment
item from the pulldown menu.
b) Click the selected adjustment item.
(The display shows White Drop Out Pixel of CCD is select-
ed)
(4) Click the [Start] button.
(5) Required procedure for adjustment is displayed on the
screen.
Follow the direction for adjustment.
(6) When the adjustment is completed normally, the box on the
left of the adjustment item is checked.
Video Signal
Filter
Frequency Counter
Oscilloscope
Audio Tester
(Insert the filter into the light box.)
Collimator
Light Box
Step Down Ring
Focus Chart
Oscilloscope
Color TV Monitor
Audio Signal
Service
Support
System
121
75 resistor for termination