1-20 (No.HC044<Rev.001>)
SECTION 5
TROUBLE SHOOTING
5.1 SERVICE MENUS
5.1.1 Modes required serviceing
Press the buttons by the combination of the following table, and press the [MENU] button. Will display the following service menus.
The items in the first layer vary according to the specified buttons being held when the [MENU] button is pressed.
(Characters are displayed on LCD monitor screen or view finder.)
5.1.2 Operation in the first layer of the service menu
(1) While holding down the specified buttons, press the
[MENU] button.
(2) The first layer of each service menu is displayed.
(3) Press the [Cross-Shaped] buttons to move the cursor ()
to the item to be displayed.
(4) Press the [Set] button or the [Cross-Shaped] button (right)
to select the item.
5.1.2.1 FIRM WARE VERSION MENU Display
(1) Turn ON the power. (DC power supply and a battery are
necessary. )
(2) While holding down the [OIS] button and the [MENU] but-
ton, turn ON the power. Then, the version of firmware is
displayed.
MENU Item Displayed content Activation method
FIRMWARE Firmware (Package) version indi-
cation
While holding down the [OIS] button and the [MENU] button, turn ON the
power.
VERSION CHECK CPU and Program version indica-
tion
Turn ON the power. The following operations are performed while hold-
ing down the [OIS] button.
• While holding down the [USER1] button and the [USER2] button,
press the [MENU] button (less than 1 second).
• And the [MENU] button is pressed again.
ADVANCED FUNCTION White blemish and camera set-
tings
Turn ON the power. The following operations are performed while hold-
ing down the [OIS] button.
• While holding down the [USER1] button and the [USER2] button,
press the [MENU] button (less than 1 second).
• And while holding down the [AF/MF] button, press the [MENU] button.
SERVICE FUNCTION Not used
DIP SW Settings of DIP SW
HOUR METER Power hour meter and slot eject
count
EEPROM Serial number input
IEEE1394ID input
NOTE :
• During recording, the service menu does not start up.
• To go back to the upper layer, press the [Cross-Shaped]
button (left).
• To cancel the service menu, press the [MENU] button.
Update Ready
Firmware SPL2470 V0002
Exit