EasyManuals Logo

K-TRON K-Commander User Manual

K-TRON K-Commander
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
805.26
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 02: Refill Parameters, Continued
Variable Name Edit? Description
Pert Value
This value is directly related to the
environmental noise. A higher
number represents more noise in
the weight signal. The minimal
value is 0. When the feeder is
stopped this value should be less
than 5. When the feeder is running
this value should be from 2-10. As
enviormental noise increases, this
value may increase to 20.
Basically this value should
remain stable. If you note that the
value is increasing or peaks, this
may cause massflow errors.
Refer to the Loss-in-Weight
Control Theory manual #4002.
There is a section that discusses
PERT.