805.47
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 05: Scale Programming and Weight Span, Continued
Determining
scale range for
entry on
page 05
If You Have ?? Then Do
If you have a scale that uses an SFT or
DFT
Read scale range from label
on scale. Enter this value for
scale range.
If you have a Modular feeder with 3
SFTs
Read the SFT range from the
side of the SFT and multiply
by 3 to get the scale range.
Enter the calculated value.
If you are unsure Call K-Tron Service for help.
Page 05 key
list
Key
Number
Key Name Description
F3 Tare Pressing this button when the
feeder hopper is empty will tare
the scale system and enter the tare
value in the Feeder Tare Weight
variable.