805.46
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 05: Scale Programming and Weight Span, Continued
Page 05
variable list
con't
Variable Name Edit? Description
Feeder Tare Weight `
#
This value represents the weight of
the feeder system less the bulk
material. This number can be
entered when this data value is
highlighted or the same result can
come from pressing the "Tare"
push-button. Please record this
value for future use.
Range of Values
0.0 Kg to 1,000,000,000 Kg or
less than Scale Range
Default value: 0.000 Kg
Weight Span ` This value will correct an error in
weight measurement.
NWS =
CWS *( applied weight/displayed weight)
where NWS = New Weight Span
CWS = current weight span.
Range of Values
0.1 to 10
Default value: 1.000
Continued on next page