K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 07: Feeder Setup Data, Continued
Page 07
variable list
The following is a listing and description of each variable on this page.
A "` " mark shows the values that you can edit. A "#" indicates that the
value is changed by a Function key.
Variable Name Edit? Description
Full Scale Setpoint
(Maximum Setpoint)
`
This entry sets the maximum value
of setpoint that you can enter on
page 0 without getting and error
message and this value also sets the
scaling for the frequency I-O that is
used by the controller.
Range of Values
0 to 90 * Scale Range Entry
Default value: 0
Units Selection `
Kg/hr <
Kg/m
lb/hr
lb/min
ton/hr
E. ton/hr
g/hr
g/min
Select the units of choice for your
operation. The units of operation
for each feeder must be the same if
you are going to work in the Line
mode of control. Default value is
"Kg/hr".
Continued on next page