805.62
K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 07: Service Variable Index, Continued
Service
variable index
and value
listing
The table below shows the Service Variable Index selections and the
Service Variable Values that can be entered or read.
Service Variable
Index
Function
Service Variable
Value Range
Calib DC (LWF only) Enter the Drv Cmd to
be used during the
Calib cycle
1 to 100% (default
10%)
Stop Clrs Alarms 0 = No
1 = Yes
Ext. Totalizer Pulse Sets the increment to
the ext. totalizer pulse
output
0.0001 to 999999
Full Scale Drv Cmd
Sets the Drive Cmd
output freq range at
100% Drive Cmd
1.000 to 40,000Hz
(default 10,000Hz)
Gear Reduction 1.000 to 999999
(default 11.00) Set at
1.000 for LWF
Gear Teeth Enter the number of
teeth on the speed
pickup gear
1 to 999999
Use Refill Array
(LWF only)
Selects whether or not
refill array is used
0 = No
1 = Yes
Refill Only Run
(LWF only)
Sets the auto refill
function to occur only
when feeder is
running
0 = No
1 = Yes
Alarm Shutdown
Mask
This entry allows you
to select which alarms
will cause an alarm
shutdown
See Alarm Shutdown
Mask procedure later
in this section
Pre Load Totalizer Allows you to
preload the totalizer
0.0000 to 999999
Continued on next page