K-Commander Loss-in-Weight Programming
Rev: G Produced by the K-Tron Institute
LWF Page 08: Frequency I/O, Continued
Page 08
variable list
The following is a listing and description of each variable on this page.
A "` " mark shows the values that you can edit. A "#" indicates that the
value is changed by a Function key.
Variable Name Edit? Description
Frequency Output 1-3 `
Not Assigned <
Massflow
Setpoint
Weight on Scale
Dev. from Setpoint
Drive Command
Screw Speed
Undefined
Dynamic Feed Factor
These outputs can be configured
for a number of different functions
as shown. The scaling chart follows
this section. Default value is " Not
Assigned".
Frequency Input 1-2 Not Used
Frequency Input #3 ` This is the ratio or direct setpoint
input for the controller if use.
Frequency Input #1-#3
Value
These variables show the incoming
frequency at these inputs.
Scaled Frequency Input
#3
This is the frequency value of Input
#3 after it has been scaled by the
Scale Factor for Input #3.