Fig. 23 Acknowledging/resetting messages
10
warning
(yellow) LED
11
alarm
(red) LED
12 «acknowledge/reset» key
Alarm message
Precondition Fault has been rectified
➤ Reset the message with the «acknowledge/reset» key.
alarm
LED extinguishes.
The machine is now ready to start again.
Warning message
Precondition The danger of an alarm is eliminated.
Maintenance has been carried out
➤ Reset the message with the «acknowledge/reset» key.
warning
LED extinguishes.
8 Operation
8.5 Acknowledging Alarm and Warning Messages