Capacitance measurement
1. Remove power from the circuit being tested. Turn the rotary function switch to ,press the
"FUNC.” key to cycle through from resistance to continuity to capacitance function.
2. Connect the black test lead to the COM terminal and the red test lead to the INPUT terminal.
3. Connect the probes across the circuit or (capacitance) component to be tested.
4. View the reading on the display.
Warning
To avoid electrical shock when testing capacitance in a circuit, make sure the power to the circuit
is turned off and all capacitors are discharged.
To avoid damaging the instrument or equipment, do not input a voltage greater than 10V.
Note:
When measuring capacitance greater than 100uF, it will take a long to measure correctly.