9. Data Setup
Using the programming software, type no. 66-99-210.
1) Current Date YY.MM.DD
The current date is programmed from the internal clock in
the computer. 10th February, 1997 is written as 97.02.10.
The data can also be changed via Kamstrup’s hand-held
terminal, MULTITERM III.
2) Current Time HH.MM.SS
The current time is programmed from the internal clock in
the computer. MAXICAL
®
III always displays seconds as
“00”
This too can be changed via Kamstrup’s hand-held terminal,
MULTITERM III.
3) Read-out Date MM.DD
The default is 1st June (06.01). However this can be
changed using MULTITERM III.
Programming limits: MM: 01...12
DD: 01...28
Data is read at midnight (2400 hrs) on the programmed date.
If you require data up to and including 31st March (03.31),
the read-out date should be programmed to 1st April
(04.01).
4) Customer ID No. Variable
The Customer ID No. can comprise of max 11 digits.
5) Average time
Average time for calculating peak power or peak flow (in
the EEPROM) can vary from 1 - 120 minutes.
6) Tariff Limits, TL2/TL3 (Please read previous chapter)
7) Alarm Limits, AL (Please read previous chapter)
8) Analogue outputs (Please read previous chapter)