The flow meter can be used in both PN16 and PN25 and can be sup-
plied marked either PN16 or PN25 as desired.
Possibly supplied glands can only be used for PN16. For PN25 installa-
tions shall be used suitable PN25 glands.
In connection with G¾x110 mm and G1x110 mm it shall be checked
that 10 mm thread run-out is sufficient. See the figure below.
Straight inlet: MULTICAL® 402 requires neither straight inlet nor straight
outlet to meet the Measuring Instruments Directive (MID) 2004/22/
EC and EN 1434:2007. A straight inlet section will only be necessary in
case of heavy flow disturbances before the meter. We recommend to
follow the guidelines of CEN CR 13582.
Gasket
Gasket
Tightening approx. 4 Nm
Gasket
Gasket
Tightening approx. 4 Nm