10.2 230 VAC supply
Includes a double-chamber safety transformer that fulfils the requirements to double-isolation. The power
consumption is lower than 3 W (without analog outputs) or less than 9 W with analog outputs.
National regulations for electric installations must be observed. The heating station’s personnel can connect/
disconnect the 230 VAC module, whereas an authorized electrician must carry out the fixed 230 V installation into
the meter panel.
10.3 24 VAC supply
Includes a double-chamber safety transformer, which fulfils the double-isolation requirements. The power
consumption is lower than 3 W (without analog outputs) or less than 9 W with analog outputs.
National regulations for electric installations must be observed. The 24 VAC module can be
connected/disconnected by the heating station’s personnel, whereas the fixed 230/24 V installation into the meter
panel must be carried out by an authorized electrician.