REMOVING THE FILTER PANES
The pane is fixed with two clamps each on
the two longitudinal edges.
Remove the pane from the spring retainer.
To do so, press the pane to be exchanged
slightly against a pair of clamps and, while
keeping it slightly pressed, tilt it out of the
holder on the relieved side.
SAFETY FUNCTION
The facial tanners are equipped with an additional
safety function. There is a protective pane-switch
behind each filter pane. This switch turns off the
tanner if the filter pane is missing or broken.
TESTING THE PROTECTIVE PANE-SWITCHES
DANGER
Excessive UV radiation
Operating the tanning device with defective filter
panes can result in serious injury to skin and eyes.
Test the protective pane-switches with each
removing of the filter panes.
Click
Press the switch. When a clicking sound is heard,
and the switch automatically return, the system is
functional.